![سامانه مدیریت نشریات علمی دانشگاه علوم پزشکی شیراز](./data/logo.png)
تعداد نشریات | 20 |
تعداد شمارهها | 1,149 |
تعداد مقالات | 10,518 |
تعداد مشاهده مقاله | 45,415,485 |
تعداد دریافت فایل اصل مقاله | 11,291,269 |
Can a Smartphone be used for Balance Assessment during Walking in Lower Limb Amputees? | ||
Journal of Rehabilitation Sciences & Research | ||
مقاله 1، دوره 7، شماره 2، شهریور 2020، صفحه 47-53 اصل مقاله (1.3 M) | ||
نوع مقاله: Original Articles | ||
شناسه دیجیتال (DOI): 10.30476/jrsr.2020.84956.1073 | ||
نویسندگان | ||
Mohammad Reza Rezaie1؛ Tahmoures Tahmasebi* 1؛ Akbar Hassanzadeh2 | ||
1Department of Orthotics and Prosthetics, School of Rehabilitation Sciences, Isfahan University of Medical Sciences, Isfahan, Iran. | ||
2Department of Epidemiology and Biostatistics, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran. | ||
چکیده | ||
Background:Nowadays, smartphones are equipped with an accelerometer module that can measure and record the body linear accelerations during walking. The aims of this study were: 1) reliability assessment of smartphone accelerometer for trunk accelerometry; 2) comparison of stability indices base on trunk accelerometry between the amputee and able-bodied subjects; and 3) comparison between energy storage and release (ESR) and multi-axis prosthetic feet users. Methods: Eleven below-knee amputees (5 multi-axis and 6 ESR prosthetic feet) and 11 able-bodied subjects enrolled in this comparative study. The dynamic stability was assessed using a smartphone attached to their back through an elastic belt during walking in a 6-m walkway. Also, normalized root mean squares (nRMS) of mediolateral (ML) and anteroposterior (AP) directions were calculated as stability indices. The intraclass correlation coefficient (ICC), standard error of measurement (SEM), SEM%, and Bland-Altman plots were used for reliability analysis. The Independent T-test was also used to compare the healthy and amputee subjects as well as ESR and multiaxis prosthetic feet users. The critical alpha was set at 0.05. Results: The results showed that the accelerometer has the ICC values more than 0.97 and 0.89 for test-retest and inter-session, respectively. Amputees had significantly higher trunk accelerations in ML direction compared to able-bodied subjects (p=0.023) but not in AP direction (p=0.496). Although the results were not significant between ESR and multi-axis prosthetic feet (AP P= 0.16, ML P=0.44), the AP stability index was higher in ESR users (AP Multi-axis=117.45, ESR=127.38). Conclusion: The smartphone can be used as a reliable measurement tool in clinical environments to assess the stability indices based on trunk accelerometry in transtibial amputees. More studies should be conducted to obtain more reliable results. | ||
کلیدواژهها | ||
Amputees؛ Stability؛ Smartphone؛ Accelerometry؛ Reliability analysis | ||
آمار تعداد مشاهده مقاله: 1,547 تعداد دریافت فایل اصل مقاله: 1,131 |