The Effect of Lubricant on the Detorque Force of Locator/Kerator Abutment in Overdenture Patients: A Pilot Clinical Study | ||
Journal of Dentistry | ||
مقالات آماده انتشار، پذیرفته شده، انتشار آنلاین از تاریخ 03 مهر 1403 اصل مقاله (762.08 K) | ||
نوع مقاله: Original Article | ||
شناسه دیجیتال (DOI): 10.30476/dentjods.2024.101754.2316 | ||
نویسندگان | ||
Ali Chamani1؛ ِِDavood Aghasizadeh2؛ Hamidreza Rajati Haghi2؛ Ghazal Aghebati3؛ Reza Shakiba* 3 | ||
1Postgraduate Student, Dept. of Endodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran. | ||
2Dept. of Prosthodontics, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran. | ||
3Student Research Committee, Faculty of Dentistry, Mashhad University of Medical Sciences, Mashhad, Iran. | ||
چکیده | ||
Statement of the Problem: Despite the implants' remarkable success, mechanical failure of implant-abutment screws is a challenge for clinicians. Among the types of mechanical failures, abutment screw loosening is still frequently reported in the literature Purpose: The present study aimed to evaluate the effect of using lubricant on the detorque force (removal force) of locator/kerator abutment in overdenture patients after 6 months of clinical usage. Materials and Method: This pilot clinical study examined the detorque force of implants in 20 edentulous patients with two mandibular implants positioned between the mental foramen. The patients underwent the fabrication of a complete maxillary prosthesis and mandibular overdenture. Before loading attachments in the delivery session, healing abutments were removed, and implant interiors dried, randomly some fixtures received a tetracycline eye ointment 1% lubricant, while the others remained non-lubricated. Abutments were secured with prescribed torque according to implant system guidelines (20 N.cm). After 6 months, detorque forces for the abutment locators were measured using a torque meter. Descriptive statistics, mean comparison, and Pearson correlation were performed on the obtained data. A significant level of P<0.05 was considered in the present study. Results: The mean detorque force was 13.4±1.94 in the non-lubricated group and 16.35± 1.24 in the lubricated group, which was significantly higher in the lubricated group (p< 0.001). Other results of the study include the non-significance of the difference in detorque force within male and female groups (p> 0.05), as well as the non-significance of Pearson's correlation between patients' age and detorque force (p> 0.05). Conclusion: According to the results, the use of lubricant significantly increases the detorque force, and it is recommended to use tetracycline eye ointment as a lubricant in implant treatment processes. | ||
کلیدواژهها | ||
Dental Implantation؛ Dental Abutments؛ Lubricants؛ Torque | ||