Investigating the Presence of SARS-CoV-2 on the Surfaces, Fomites, and in Indoor Air of a Referral COVID-19 Hospital, Shiraz, Iran | ||
| Journal of Health Sciences & Surveillance System | ||
| دوره 11، 1 (Supplementary of COVID - 19)، بهار 2023، صفحه 241-251 اصل مقاله (906.17 K) | ||
| نوع مقاله: Original Article | ||
| شناسه دیجیتال (DOI): 10.30476/jhsss.2022.94013.1502 | ||
| نویسندگان | ||
| Ehsan Gharehchahi1؛ Fatemeh Dehghani2؛ Ata Rafiee3؛ Marzieh Jamalidoust4؛ Mohammad Hoseini* 5 | ||
| 1Department of Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran | ||
| 2Shiraz University of Medical Sciences, Shiraz, Iran | ||
| 3Department of Medicine, University of Alberta, Edmonton, AB, Canada | ||
| 4Department of Virology, Professor Alborzi Clinical Microbiology Research Center, Namazi Hospital, Shiraz University of Medical Sciences, Shiraz, Iran | ||
| 5Research Center for Health Sciences, Institute of Health, Department of Environmental Health Engineering, School of Health, Shiraz University of Medical Sciences, Shiraz, Iran | ||
| چکیده | ||
| Background: Coronavirus disease (COVID-19) is an immensely transmissible viral infectious disease caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). This study aimed to assess the presence of SARS-CoV-2 in the indoor air, on the surfaces, and on the fomites of a COVID-19 referral hospital in Shiraz, Iran. Methods: In this cross-sectional study, indoor air sampling was conducted utilizing a standard midget impinger containing 15 ml of viral transfer medium (VTM) equipped with a sampling pump with a flow rate of 10 L min-1 for 60 minutes. Surfaces and fomites were sampled using sterile polyester swabs. The realtime reverse transcription-polymerase chain reaction (rRT-PCR) was utilized to detect SARS-CoV-2. Results: The RNA of SARS-CoV-2 was detected in about 41.2% indoor air and 32% swab samples. Four out of the six (66.7%) indoor air samples up to a distance of 2 meters from the patient’s bed in intensive care units (ICU-1, ICU-3), accident and emergency (A&E-2), and negative pressure rooms were positive for SARS-CoV-2 RNA. All air samples within 2 to 5 meters of the patient’s bed were negative. Conclusion: This study’s results did not support the airborne SARS-CoV-2 transmission; However, it showed contamination of surfaces and fomites in the studied hospital’s wards. | ||