- Westbrook C, Kaut C. MRI in Practice. 2nd ed. Osney Mead: Blackwell Science, Oxford; 2002. Chapter 6.
- Nazarpoor M. Inflow effect of signal intensity for the Center out Phase-Encoding and Linear Phase-Encoding acquisitions on inversion recovery T1-weighted TurboFLASH images. J Cardiovasc Thorac Res. 2009;1(4):29-37.
- Pettersson H, Allison D. The encyclopedia of medical imaging Volume 1 Physics, Techniques and Procedures. Sweden: NICER Institute; 1988.
- Moody AR, Martel A, Kenton A, Allder S, Horsfield MA, Delay G, Morgan P. Contrast-reduced imaging of tissue concentration and arterial level (CRITICAL) for assessment of cerebral hemodynamics in acute stroke by magnetic resonance. Invest Radiol. 2000;35(7):401-11. doi: 10.1097/00004424-200007000-00002. PubMed PMID: 10901101.
- Nazarpoor M. Evaluation of flow measurement from the first pass bolus T1 weighted images using inversion recovery sequence. Br J Radiol. 2011;84(1000):342-9. doi: 10.1259/bjr/18588668. PubMed PMID: 20959366. PubMed PMCID: PMC3473463.
- Nazarpoor M, Morgan PS. Inflow effect correction on perfusion measurement of normal subjects with T1-weighted images using inversion recovery sequences. Iran J Radiol. 2010;7(3):145-51.
- Nazarpoor M. Effect of concentration of contrast agent on the inflow effect for measuring absolute perfusion by use of inversion recovery T1-weighted TurboFLASH images. Radiol Phys Technol. 2012;5(1):86-91. doi: 10.1007/s12194-011-0140-3. PubMed PMID: 22113425.
- Nazarpoor M. Effect of phase-encoding scheme on the relationship between contrast agent concentration and signal intensity on inversion recovery turbo fast low-angle shot T1-weighted images. Radiol Phys Technol. 2014;7(2):262-70. doi: 10.1007/s12194-014-0260-7. PubMed PMID: 24500244.
- Nazarpoor M. Effects of inversion and saturation times on relationships between contrast agent concentrations and signal intensities of T1-weighted magnetic resonance images. Radiol Phys Technol. 2010;3(2):120-6. doi: 10.1007/s12194-010-0087-9. PubMed PMID: 20821085.
- Nazarpoor M, Gharehaghaji N, Saharkhiz H. Effect of Inversion Time on the Linear Correlation between Polyethylene Glycol Coated Iron Oxide Nanoparticles Concentration and Signal Intensity in Inversion Recovery MRI Pulse Sequence. J Mazandaran Univ Med Sci. 2015;24(122):88-97.
- Nazarpoor M. Evaluation of Maximum and Minimum Signal Intensity and the Linear Relationship between Concentration and Signal Intensity in Saturation Recovery T1-weighted Images by use of a Turbo Fast Low-Angle Shot Sequence. J Biomed Phys Eng. 2020;10(4):449-58. doi: 10.31661/jbpe.v0i0.823. PubMed PMID: 32802793. PubMed PMCID: PMC7416098.
- Nazarpoor M, Poureisa M, Daghighi MH. Effect of echo time on the maximum relationship between contrast agent concentration and signal intensity using FLAIR sequence. Iranian Journal of Medical Physics. 2013;10(1):59-67.
- Nazarpoor M. The effect of repetition time on the maximum linear relationship between contrast agent concentration and signal intensity on T1 weighted image using inversion recovery (IR) sequence. Iran J Radiol. 2009;6(4):247-52.
- Gharehaghaji N, Nazarpoor M, Saharkhiz H. Effect of Flip Angle on the Correlation Between Signal Intensity and Different Concentrations of Iron Oxide Nanoparticles Using T1-Weighted Turbo-FLASH Inversion Recovery Sequence. Iran J Radiol. 2015;12(2):e22887. doi: 10.5812/iranjradiol.22887. PubMed PMID: 25901260. PubMed PMCID: PMC4389174.
- Nazarpoor M, Poureisa M, Daghighi MH. Comparison of maximum signal intensity of contrast agent on t1-weighted images using spin echo, fast spin echo and inversion recovery sequences. Iran J Radiol. 2012;10(1):27-32. doi: 10.5812/iranjradiol.5452. PubMed PMID: 23599710. PubMed PMCID: PMC3618902.
- Gharehaghaji N, Nazarpoor M, Saharkhiz H. Effect of iron oxide nanoparticles coating type on the relationship between nanoparticles concentration and signal intensity in inversion recovery T1-weighted MRI. Med J Islam Repub Iran. 2015;29:211. PubMed PMID: 26478869. PubMed PMCID: PMC4606948.
- Nazarpoor M, Mayabi Z, Shfaie A, Pesianian E, Aghaverdizadeh D. Maximum relationship between signal intensity and concentration of contrast agent in 0.3 T and 1.5 T using T1-weighted spin echo sequence. Medical Journal of Tabriz University of Medical Sciences & Health services. 2011;32(6):72-6.
- Akbudak E, Norberg RE, Conturo TE. Contrast-agent phase effects: an experimental system for analysis of susceptibility, concentration, and bolus input function kinetics. Magn Reson Med. 1997;38(6):990-1002. doi: 10.1002/mrm.1910380619. PubMed PMID: 9402201.
- Soustiel JF, Levy E, Zaaroor M, Bibi R, Lukaschuk S, Manor D. A new angle-independent Doppler ultrasonic device for assessment of blood flow volume in the extracranial internal carotid artery. J Ultrasound Med. 2002;21(12):1405-12. doi: 10.7863/jum.2002.21.12.1405. PubMed PMID: 12494983.
- Savin E, Siegelova J, Fisher B, Bonnin P. Intra- and extracranial artery blood velocity during a sudden blood pressure decrease in humans. Eur J Appl Physiol Occup Physiol. 1997;76(3):289-93. doi: 10.1007/s004210050250. PubMed PMID: 9286611.
- Smith JJ, Kampine JP. Circulatory Physiology - The essentials. Third edition. Baltimore, Maryland, USA: Williams & Wilkins; 1990.
- Goyen M, Lauenstein TC, Herborn CU, Debatin JF, Bosk S, Ruehm SG. 0.5 M Gd chelate (Magnevist) versus 1.0 M Gd chelate (Gadovist): dose-independent effect on image quality of pelvic three-dimensional MR-angiography. J Magn Reson Imaging. 2001;14(5):602-7. doi: 10.1002/jmri.1225. PubMed PMID: 11747013.
- Nazarpoor M. Non-uniformity of Clinical Head, Head and Neck, and Body Coils in Magnetic Resonance Imaging (MRI). Iranian Journal of Medical Physics. 2014;11(4):322-7. doi: 10.22038/ijmp.2014.3569.
- Nazarpoor M. Organ blood flow measurement with T1 and T2*-weighted MRI techniques. Saarbrücken, Germany: LAP Lambert Academic Publishing; 2012.
- Dean BL, Lee C, Kirsch JE, Runge VM, Dempsey RM, Pettigrew LC. Cerebral hemodynamics and cerebral blood volume: MR assessment using gadolinium contrast agents and T1-weighted Turbo-FLASH imaging. AJNR Am J Neuroradiol. 1992;13(1):39-48. PubMed PMID: 1595482. PubMed PMCID: PMC8331784.
- Hackländer T, Reichenbach JR, Hofer M, Mödder U. Measurement of cerebral blood volume via the relaxing effect of low-dose gadopentetate dimeglumine during bolus transit. AJNR Am J Neuroradiol. 1996;17(5):821-30. PubMed PMID: 8733953. PubMed PMCID: PMC8337506.
- Ivancevic MK, Zimine I, Montet X, Hyacinthe JN, Lazeyras F, Foxall D, Vallée JP. Inflow effect correction in fast gradient-echo perfusion imaging. Magn Reson Med. 2003;50(5):885-91. doi: 10.1002/mrm.10633. PubMed PMID: 14586998.
- Nazarpoor M. The effect of inversion times on the minimum signal intensity of the contrast agent concentration using inversion recovery t1-weighted fast imaging sequence. Med J Islam Repub Iran. 2014;28:128. PubMed PMID: 25679007. PubMed PMCID: PMC4313446.
- Peeters F, Annet L, Hermoye L, Van Beers BE. Inflow correction of hepatic perfusion measurements using T1-weighted, fast gradient-echo, contrast-enhanced MRI. Magn Reson Med. 2004;51(4):710-7. doi: 10.1002/mrm.20032. PubMed PMID: 15065243.
- Pang Y, Bernardo M, Turkbey B, Ravizzini G, Thom-asson D, Choyke P. Minimizing Inflow Effect in Measured Arterial Input Function for Prostate DCE-MRI. Proc Intl Soc Mag Reson Med. 2008;16:2775.
- Vallée JP, Lazeyras F, Khan HG, Terrier F. Absolute renal blood flow quantification by dynamic MRI and Gd-DTPA. Eur Radiol. 2000;10(8):1245-52. doi: 10.1007/s003300000434. PubMed PMID: 10939483.
- Montet X, Ivancevic MK, Belenger J, Jorge-Costa M, Pochon S, Pechère A, et al. Noninvasive measurement of absolute renal perfusion by contrast medium-enhanced magnetic resonance imaging. Invest Radiol. 2003;38(9):584-92. doi: 10.1097/01.RLI.0000077127.11949.8c. PubMed PMID: 12960528.
- Barbier EL, Lamalle L, Décorps M. Methodology of brain perfusion imaging. J Magn Reson Imaging. 2001;13(4):496-520. doi: 10.1002/jmri.1073. PubMed PMID: 11276094.
- Rempp KA, Brix G, Wenz F, Becker CR, Gückel F, Lorenz WJ. Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging. Radiology. 1994;193(3):637-41. doi: 10.1148/radiology.193.3.7972800. PubMed PMID: 7972800.
- Ito H, Takahashi K, Hatazawa J, Kim SG, Kanno I. Changes in human regional cerebral blood flow and cerebral blood volume during visual stimulation measured by positron emission tomography. J Cereb Blood Flow Metab. 2001;21(5):608-12. doi: 10.1097/00004647-200105000-00015. PubMed PMID: 11333371.
|