- Judy PF, Balter S, Bassano D, McCullough EC, Payne JT, Rothenberg L. Phantoms for performance evaluation and quality assurance of CT scanners. AAPM Report No. 1; Chicago (IL): American Association of Physicists in Medicine; 1977.
- Och JG, Clarke GD, Sobol WT, Rosen CW, Mun SK. Acceptance testing of magnetic resonance imaging systems: report of AAPM Nuclear Magnetic Resonance Task Group No. 6. Med Phys. 1992;19(1):217-29. doi: 10.1118/1.596903. PubMed PMID: 1620053.
- Amendoeira I, et al. European guidelines for quality assurance in breast cancer screening and diagnosis. Belgium: European Commission; 2013. p. 55-71.
- Goodsitt MM, Carson PL, Witt S, Hykes DL, Kofler JM. Real-time B-mode ultrasound quality control test procedures. Report of AAPM Ultrasound Task Group No. 1. Med Phys. 1998;25(8):1385-406. doi: 10.1118/1.598404. PubMed PMID: 9725125.
- Acri G, Tripepi MG, Causa F, Testagrossa B, Novario R, Vermiglio G. Slice-thickness evaluation in CT and MRI: an alternative computerised procedure. Radiol Med. 2012;117(3):507-18. doi: 10.1007/s11547-011-0775-5. PubMed PMID: 22228130.
- Boone JM, Cody DD, Fisher JR, Frey GD, Glasser H, Gray JE, Haus AG, et al. Quality control in diagnostic radiology. AAPM Report No. 74; Madison (WI): American Association of Physicists in Medicine; 2002.
- Walker TF, Mah P, Dove SB, McDavid WD. Digital intraoral radiographic quality assurance and control in private practice. General Dentistry. 2014;62(5):22-9. PubMed PMID: 25184710.
- Hatziioannou K, Psarouli E, Papanastassiou E, Bousbouras P, et al. Quality control and diagnostic reference levels in intraoral dental radiographic facilities. Dentomaxillofacial Radiology. 2005;34(5):304-7. doi: 10.1259/dmfr/38802780. PubMed PMID: 16120881.
- Cederberg R. Intraoral digital radiography: elements of effective imaging. Compend Contin Educ Dent. 2012;33(9):656. PubMed PMID: 23030728.
- National Council on Radiological Protection and Measurement. Radiation protection in dentistry. NCRP Report No. 145; Bethesda (MD): NCRP; 2003.
- Kwan AL, Ching H, Gray JE, Massoth RJ, McDavid WD, Platin E, et al. Acceptance Testing and Qual- ity Control of Dental Imaging Equipment. AAPM Report No. 175; Alexandria (VA): American Association of Physicists in Medicine; 2016.
- Udupa H, Mah P, Dove SB, McDavid WD. Evaluation of image quality parameters of representative intraoral digital radiographic systems. Oral Surg Oral Med Oral Pathol Oral Radiol. 2013;116(6):774-83. doi: 10.1016/j.oooo.2013.08.019. PubMed PMID: 24237729.
- Sanderink GC, Miles DA. Intraoral detectors. CCD, CMOS, TFT, and other devices. Dental Clinics of North America. 2000;44(2):249-55. PubMed PMID: 10740767.
- Paurazas SB, Geist JR, Pink FE, et al. Comparison of digital imaging using CCD and CMOS-APS sensors with E-spead film in the detection of periapical bony lesions. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2000;89:356-62. doi: 10.1016/s1079-2104(00)70102-8. PubMed PMID: 10710463.
- Kashima I. Computed radiography with photostimulable phosphor in oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1995;80(5):577-98. doi: 10.1016/S1079-2104(05)80155-6. PubMed PMID: 8556466.
- Sonoda M, Takano M, Miyahara J, Kato H. Computed radiography utilizing scanning laser stimulated luminescence. Radiology. 1983;148(3):833-8. doi: 10.1148/radiology.148.3.6878707. PubMed PMID: 6878707.
- Bonanno L, Marino S, Morabito R, Barbalace G, et al. Evaluation of US and MRI techniques for carotid stenosis: a novel phantom approach. Radiol Med. 2019;124(5):368-74. doi: 10.1007/s11547-018-0971-7. PubMed PMID: 30542910.
- Mah P, McDavid WD, Dove SB. Quality assurance phantom for digital dental imaging. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2011;112(5):632-9. doi: 10.1016/j.tripleo.2011.05.015. PubMed PMID: 21862364.
- Yakoumakis EN, Tierris CE, Stefanou EP, et al. Image quality assessment and radiation doses in in- traoral radiography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2001;91(3):362-8. doi: 10.1067/moe.2001.111940.
- Yoshiura K, Kawazu T, Chikui T, Tatsumi M, Tokumori K, Tanaka T, Kanda S. Assessment of image quality in dental radiography, part 1: phantom validity. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 1999;87(1):115-22. doi: 10.1016/s1079-2104(99)70304-5. PubMed PMID: 9927090.
- Dashpuntsag O, Yoshida M, Kasai R, et al. Numerical evaluation of image contrast for thicker and thinner objects among current intraoral digital imaging systems. Biomed Res Int. 2017;2017:5215413. doi: 10.1155/2017/5215413. PubMed PMID: 28497053. PubMed PMCID: PMC5401743.
- Pittayapat P, Oliveira-Santos C, Thevissen P, et al. Image quality assessment and medical physics evaluation of different portable dental X-ray units. Forensic Science International. 2010;201(1-3):112-7. doi: 10.1016/j.forsciint.2010.04.041. PubMed PMID: 20554135.
- Collamati L, Filippetti F, Franceschini G, Pirani S, Tassoni C. Induction machine stator fault on-line diagnosis based on LabVIEW environment. Proceedings of 8th Mediterranean Electrotechnical Conference on Industrial Applications in Power Systems, Computer Science and Telecommunications (MELECON 96); Bari, Italy: IEEE; 1996. p. 495-8.
- National Instrument. LabVIEW TM User Manual. April 2003. Available from: https://www.ni.com/pdf/manuals/320999e.pdf.
- Elliott C, Vijayakumar V, Zink W, Hansen R. National instruments LabVIEW: a programming environment for laboratory automation and measurement. JALA. 2007;12(1):17-24. doi: 10.1016/j.jala.2006.07.012.
- Acri G, Testagrossa B, Sestito A, Bonanno L, Vermiglio G. CT and MRI slice separation evaluation by LabView developed software. Zeitschrift für Medizinische Physik. 2018;28(1):6-13. doi: 10.1016/j.zemedi.2017.09.009.
- Gulliksrud K, Stokke C, Martinsen AC. How to measure CT image quality: variations in CT-numbers, uniformity and low contrast resolution for a CT quality assurance phantom. Physica Medica. 2014;30(4):521-6. doi: 10.1016/j.ejmp.2014.01.006. PubMed PMID: 24530005.
- Racine D, Viry A, Becce F, Schmidt S, et al. Objective comparison of high-contrast spatial resolution and low-contrast detectability for various clinical protocols on multiple CT scanners. Med Phys. 2017;44(9):e153-63. doi: 10.1002/mp.12224. PubMed PMID: 28901621.
- Vermiglio G, Testagrossa B, Acri G, Tripepi MG, Marino S, Bramanti P. MRI and CT Slice Thickness Evaluation by Computerized Dedicated Procedures. World Congress on Medical Physics and Biomedical Engineering; Munich, Germany: Springer; 2009 p. 924-7. doi: 10.1007/978-3-642-03474-9-259.
- Price RR, Axel L, Morgan T, Newman R, Perman W, Schneiders N, et al. Quality assurance methods and phantoms for magnetic resonance imaging: report of AAPM nuclear magnetic resonance Task Group No. 1. Med Phys. 1990;17(2):287-95. doi: 10.1118/1.596566. PubMed PMID: 2333055.
- Erasmus LJ, Hurter D, Naudé M, Kritzinger HG, Acho S. A short overview of MRI artefacts. South African Journal of Radiology. 2004;8(2)13-7. doi: 10.4102/sajr.v8i2.127.
- MathWorks [Internet]. Lilliefors test – MATLAB lillietest – MathWorks Italia; 2019 Feb 13 [cited 2019 Mar 11]. Available from: https://it.mathworks.com/help/stats/lillietest.html.
- Hogg RV, Ledolter J. Engineering Statistics. New York: MacMillan; 1987. p. 442.
- MathWorks [Internet]. One-way analysis of variance – MATLAB anova1 – MathWorks Italia; 2019 Feb 15 [cited 2019 Mar 11]. Available from: https://it.mathworks.com/help/stats/anova1.html.
- Hochberg Y, A Tamhane. Multiple Comparison Procedures. Hoboken, NJ: John Wiley; 1987.
- MathWorks [Internet]. Multiple comparison test - MATLAB multcompare - MathWorks Italia; 2019 Feb 13 [cited 2019 Mar 11]. Available from: https://it.mathworks.com/help/stats/multcompare.html.
- Fleiss JL, Cohen J. The equivalence of weighted kappa and the intraclass correlation coefficient as measures of reliability. Educational and Psychological Measurement. 1973;33(3):613-9. doi: 10.1177/001316447303300309.
|