چکیده
Background: In developing countries like India, cobalt-60 machines still find their applicability, considering the cost and maintenance issues. With a view to deliver conformal treatment plans using teletherapy machines, an automated Multi-Leaf Collimator (MLC) was developed for the existing machines as a retrofit attachment to the collimator assembly without any modifications to the unit. Objective: This study aims to investigate the radiation characteristics of leaf designs incorporated in two add-on prototype MLC systems with respect to the shape of leaf projected at the isocenter plane and the isodose distribution around the target. Besides, the dosimetric characteristics of prototype MLC with divergent leaf design are validated through simulation and experimental measurements. Material and Methods: In this experimental study, two add-on prototype MLC systems were designed and fabricated. The characteristic measurements of leaf designs incorporated in both the prototypes were carried out using Gafchromic films (GAF) and compared with Monte Carlo (MC) simulations. For divergent leaf design, beam profiles were obtained using Monte Carlo simulations which are complemented with the results obtained from measurements of radiochromic films and ionization chamber (IC) profiler. Dosimetric characteristics like radiation field width and beam penumbra were evaluated. Results: The Monte Carlo simulated data are in agreement with experimental data from IC profiler as well as from Radiochromic films. The results of this study are well within acceptable tolerance limits. Conclusion: The prototype MLC system designed for existing telecobalt machines supports its clinical applicability for conformal therapy to better manage treatment in rural areas, which can provide superior cost effective treatments.
Munshi A, Ganesh T, Mohanti BK. Radiotherapy in India: History, current scenario and proposed solutions. Indian J Cancer. 2019;56(4):359-63. doi: 10.4103/ijc.IJC_82_19. PubMed PMID: 31607709.
Jayarajan K, Kar DC, Sahu R, Radke MG, Singh M. BARC develops cobalt-60 teletherapy machine for cancer treatment. BARC Newsletter; Mumbai: Bhabha Atomic Research Centre; 2005.
Ravichandran R. Has the time come for doing away with Cobalt-60 teletherapy for cancer treatments. J Med Phys. 2009;34(2):63-5. doi: 10.4103/0971-6203.51931. PubMed PMID: 20098538. PubMed PMCID: PMC2805891.
Van Dyk J, Battista JJ. Cobalt-60: An old modality, a renewed challenge. Curr Oncol. 1996;3:8-17.
Rani AR, Ayyangar K, Reddy AR, Kumar AA, Reddy PR. Design and development of an add-on automated multi leaf collimator for telecobalt therapy machine and study of its characteristics. Int J Cancer Ther Oncol. 2018;6(1):19-30.
Galvin JM, Han K, Cohen R. A comparison of multileaf-collimator and alloy-block field shaping. Int J Radiat Oncol Biol Phys. 1998;40(3):721-31. doi: 10.1016/s0360-3016(97)00815-8. PubMed PMID: 9486625.
Galvin JM, Leavitt DD, Smith AA. Field edge smoothing for multileaf collimators. Int J Radiat Oncol Biol Phys. 1996;35(1):89-94. doi: 10.1016/s0360-3016(96)85015-2. PubMed PMID: 8641931.
Ayyangar KM, Reddy AR. Development of an automated MLC for telecobalt therapy machine with a potential for conformal therapy. Proceedings of 32nd Annual conference of Association of Medical Physicists of India; India: CMCH Vellore; 2011.
Akula RR, Anil Kumar A, Talluri AK, Sresty M, Rao CR, Sankaranarayana M, et al. Calibration measurements on the prototype MLC for cobalt 60 teletherapy machine. Proceedings of 33rd Annual conference of Association of Medical Physicists of India; India, Mangalore: Association of Medical Physicists; 2012.
Roopa Rani A, Ayyangar KM, Reddy AR, Anil Kumar A, Yadagiri Reddy PR. Experimental verification of Monte Carlo simulations of MLC fields for Cobalt-60 therapy machine. Proceedings of 35th Annual Conference of Association of Medical Physicists of India; India, Loni: Association of Medical Physicists; 2014. p. 105.
Ayyangar KM, Rani RA, Kumar A, Reddy AR. Monte Carlo study of MLC fields for cobalt therapy machine. J Med Phys. 2014;39(2):71-84. doi: 10.4103/0971-6203.131279. PubMed PMID: 24872604. PubMed PMCID: PMC4035619.
Boyer A, Biggs P, Galvin J, Klein E, Losasso T, Low D, et al. Basic applications of multileaf collimators. AAPM Report NO. 72; United States: American Association of Physicists in Medicine; 2001.
Kumar AA, Akula RR, Ayyangar K, Krishna RP, Vuppu S, Narayana PV, Rao AD. In-house quality check of external beam plans using 3D treatment planning systems - a DVH comparison. J Appl Clin Med Phys. 2016;17(3):138-46. doi: 10.1120/jacmp.v17i3.6020. PubMed PMID: 27167271. PubMed PMCID: PMC5690922.
Krishna GS, Akula RR, Kumar AA, Srinivas V, Ayyangar K, Reddy PY. DVH Analysis of Cobalt-60 treatment plans incorporating a recently developed MLC. Int J Cancer Ther Oncol. 2016;4(3):431. doi: 10.14319/IJCTO.43.1.
Niroomand-Rad A, Blackwell CR, Coursey BM, et al. Radiochromic film dosimetry: recommendations of AAPM Radiation Therapy Committee Task Group 55. American Association of Physicists in Medicine. Med Phys. 1998;25(11):2093-115. doi: 10.1118/1.598407. PubMed PMID: 9829234.
International Electro technical Commission. Part2: Particular requirements for the safety of gamma beam therapy equipment. Report No. IEC-60601- 2-11; Geneva: IEC; 1997.
Atomic Energy Regulatory Board. AERB safety code for radiation therapy sources, equipment and installations. AERB SAFETY CODE NO. AERB/RF-MED/SC-1 (Rev. 1); India: AERB; 2011.