تعداد نشریات | 20 |
تعداد شمارهها | 1,149 |
تعداد مقالات | 10,518 |
تعداد مشاهده مقاله | 45,415,485 |
تعداد دریافت فایل اصل مقاله | 11,291,272 |
Rapid and specific chromatography method on monolithic RP-column for determination of high-dose methotrexate pharmacokinetics in sera of cancer patients admitted to Shiraz Amir Hospital | ||
Trends in Pharmaceutical Sciences | ||
مقاله 3، دوره 6، شماره 3، آذر 2020، صفحه 163-174 اصل مقاله (635.15 K) | ||
نوع مقاله: Original Article | ||
شناسه دیجیتال (DOI): 10.30476/tips.2020.87523.1062 | ||
نویسندگان | ||
Lida Shojaei1؛ Fakhrsadat Farvadi2؛ Soheila Zareifar3؛ Samirasadat Abolmaali4؛ Soha Namazi* 5؛ Alimohammad Tamaddon6 | ||
1Pharmaceutical Sciences Research Center, Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran | ||
2Center for Nanotechnology in Drug Delivery, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran | ||
3Oncology Amir Hospital, Shiraz University of medical sciences, Shiraz, Iran | ||
4Center for Nanotechnology in Drug Delivery and Department of Pharmaceutical Nanotechnology, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran | ||
5Department of Pharmacotherapy, Tehran University of medical sciences, Tehran, Iran | ||
6Center for Nanotechnology in Drug Delivery, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz 71345, Iran | ||
چکیده | ||
Introduction: methotrexate (MTX) is a routinely used antifolate for the treatment of solid tumors and hematologic malignancies. However, high-dose MTX can lead to severe side effects and the patients are required to receive leucovorin rescue. Hence, we aimed to develop a fast and specific HPLC method for monitoring MTX level in sera of cancer patients. Methods: HPLC analysis was carried out on a Chromolith RP-18 monolithic column. The assay method was validated in terms of specificity, linearity, accuracy, precision, and limit of quantification. Using pharmacokinetic equations and limited blood sampling from each patient at 24 and 48 h after initiation of MTX therapy, it was attempted to predict the serum MTX level for discontinuation of leucovorin. Results: the HPLC assay method was successfully validated for determination of the MTX level in combination with other concomitantly used drugs in the sera of cancer patients with a considerable decline in the analysis time (a total run time of less than 4 min). In addition, the HPLC assay method was favorably applied to the determination of MTX pharmacokinetic parameters using two-compartmental model approach. It was revealed that the MTX levels were in toxic range in some patients and the MTX pharmacokinetic parameters varied in range of 17-97% among the patients. Conclusion: monitoring the MTX level in patient serum, especially when prescribed in high doses, is highly demanded. | ||
کلیدواژهها | ||
methotrexate؛ monolithic column؛ liquid chromatography؛ pharmacokinetics؛ therapeutic drug monitoring | ||
آمار تعداد مشاهده مقاله: 8,626 تعداد دریافت فایل اصل مقاله: 1,081 |