تعداد نشریات | 20 |
تعداد شمارهها | 1,149 |
تعداد مقالات | 10,518 |
تعداد مشاهده مقاله | 45,415,538 |
تعداد دریافت فایل اصل مقاله | 11,291,340 |
Effect of Shade and Thickness on the Depth of Cure of Bulk-Fill Composites with Different Viscosities | ||
Journal of Dentistry | ||
مقاله 9، دوره 21، شماره 4 - شماره پیاپی 69، اسفند 2020، صفحه 322-329 اصل مقاله (689.31 K) | ||
نوع مقاله: Original Article | ||
شناسه دیجیتال (DOI): 10.30476/dentjods.2020.83927.1061 | ||
نویسندگان | ||
Maryam Novin Rooz1؛ Atefeh Yousefi Jordehi* 2 | ||
1Dentist, Dept. of Operative Dentistry, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran. | ||
2Dept. of Operative Dentistry, School of Dentistry, Zanjan University of Medical Sciences, Zanjan, Iran. | ||
چکیده | ||
Statement of the Problem: In an attempt to fasten and simplify the restoration process, a new class of composite resins, called the bulk fill composite resins have been introduced, which has been claimed to achieve a depth of cure (DOC) of 4 mm without affecting the properties of the material. Purpose: The Purpose of this study was to investigate the effect of different shades, thicknesses and viscosities on the DOC of bulk-fill composites. Materials and Method: Four bulk-fill composites [FiltekTMBulkfill Flowable (FBF), FiltekTM Bulkfill posterior (FBP), Tetric N-Flow bulkfill(TNF), Tetric N-Ceram bulkfill(TNC)] and a conventional composite, FiltekTM Z250XT Universal (FZ) were evaluated. samples (n=5) were made using two different shades( light and dark), thicknesses (2 and 4mm) and viscosities (flowable and sculptable). Microhardness was conducted on top and bottom surface using Vickers microhardness tester and DOC calculated as the bottom/top ratio. Statistical analysis was done using a mannwhitney test at p < 0.05. Results: DOC ranged between 52-95%. FBF composite exhibited the lowest overall hardness numbers. At 2-mm thickness, all the samples achieved an appropriate DOC. However, at 4-mm thickness, only the light shades for FBF and TNF samples achieved a DOC very close to 0.8. At 4-mm thickness, the light shades for FBF, TNF and FZ samples exhibited significantly higher DOC compared to dark shades. For 4-mm-thick samples, DOC of FB )dark and light shades (and DOC of TN (light shade( were different in the flowable type from the sculptable type. Conclusion: Shade and viscosity influence DOC of bulk-fill composites at 4-mm depths. For bulk-fill composites, 20s light curing appears insufficient for 4mm bulk-fill placement. | ||
کلیدواژهها | ||
Bulk-fill composites؛ Microhardness؛ Thickness؛ Depth of cure؛ Shade | ||
سایر فایل های مرتبط با مقاله
|
||
مراجع | ||
[1] Momoi Y, Hayashi M, Fujitani M, Fukushima M, Imazato S, Kubo S, et al. Clinical guidelines for treating caries in adults following a minimal intervention policy- evidence and consensus based report. Journal of Dentistry. 2012; 40: 95-105. [2] Ferracane JL. Resin composite-state of the art. Dental materials. 2011; 27: 29-38. [3] Miletic V, Pongprueksa P, De*Munck J, Brooks NR, Van*Meerbeek B. Curing characteristics of flowable and sculptable bulk-fill composites. Clinical oral investigations. 2017; 21: 1201-1212. [4] Ilie N, Bucuta S, Draenert M. Bulk-fill resin-based composites: an in vitro assessment of their mechanical performance. Operative Dentistry. 2013; 38: 618-625. [5] Alrahlah A, Khan R, Alotaibi K, Almutawa Z, Fouad H, Elsharawy M, et al. Simultaneous Evaluation of Creep Deformation and Recovery of Bulk-Fill Dental Composites Immersed in Food-Simulating Liquids. Materials (Basel, Switzerland). 2018; 11: 1180. [6] Rizzante FAP, Mondelli RFL, Furuse AY, Borges AFS, Mendonca G, Ishikiriama SK. Shrinkage stress and elastic modulus assessment of bulk-fill composites. J Appl Oral Sci. 2019; 27: e20180132. [7] Tsujimoto A, Nagura Y, Barkmeier WW, Watanabe H, Johnson WW, Takamizawa T, et al. Simulated cuspal deflection and flexural properties of high viscosity bulk-fill and conventional resin composites. J Mech Behav Biomed Mater. 2018; 87: 111-118. [8] Behery H, El-Mowafy O, El-Badrawy W, Nabih S, Saleh B. Gingival microleakage of class II bulk-fill composite resin restorations. Dental and Medical Problems. 2018; 55: 383-388. [9] Sahadi BO, Price RB, Andre CB, Sebold M, Bermejo GN, Palma-Dibb RG, et al. Multiple-peak and single-peak dental curing lights comparison on the wear resistance of bulk-fill composites. Braz Oral Res. 2018; 32: e122. [10] Fleming GJP, Awan M, Cooper PR, Sloan AJ. The potential of a resin-composite to be cured to a 4mm depth. Dental Materials. 2008; 24: 522-529. [11] Alshaafi MM, Haenel T, Sullivan B, Labrie D, Alqahtani MQ, Price RB. Effect of a broad-spectrum LED curing light on the Knoop microhardness of four posterior resin based composites at 2, 4 and 6-mm depths. Journal of Dentistry. 2016; 45(Supplement C): 14-18. [12] Jain L, Mehta D, Meena N, Gupta R. Influence of Light Energy Density, Composite Type, Composite Thickness, and Postcuring Phase on Degree of Conversion of Bulk-fill Composites. Contemp Clin Dent. 2018; 9: 147-152. [13] Rueggeberg F, Caughman WF, Curtis J. Effect of light intensity and exposure duration on cure of resin composite. Operative dentistry. 1994; 19: 26-32. [14] Ferracane JL. Correlation between hardness and degree of conversion during the setting reaction of unfilled dental restorative resins. Dental Materials. 1985; 1: 11-14. [15] Farahat F, Daneshkazemi AR, Hajiahmadi Z. The effect of bulk depth and irradiation time on the surface hardness and degree of cure of bulk-fill composites. J Dent Biomater. 2016; 3: 284–291. [16] Aggarwal N, Jain A, Gupta H, Abrol A, Singh C, Rapgay T. The comparative evaluation of depth of cure of bulk-fill composites- An in vitro study. J Conserv Dent. 2019; 22: 371-375. [17] Ilie N, Stark K. Curing behaviour of high-viscosity bulk-fill composites. Journal of Dentistry. 2014; 42: 977-985. [18] Nagi SM, Moharam LM, Zaazou MH. Effect of resin thickness, and curing time on the micro-hardness of bulk-fill resin composites. Journal of Clinical and Experimental Dentistry. 2015; 7: e600-e604. [19] Rodriguez A, Yaman P, Dennison J, Garcia D. Effect of Light-Curing Exposure Time, Shade, and Thickness on the Depth of Cure of Bulk Fill Composites. Oper Dent. 2017; 42: 505-513. [20] Son SA, Park JK, Seo DG, Ko CC, Kwon YH. How light attenuation and filler content affect the microhardness and polymerization shrinkage and translucency of bulk-fill composites? Clin Oral Investig. 2017; 21: 559-565. [21] Garoushi S, Vallittu P, Shinya A, Lassila L. Influence of increment thickness on light transmission, degree of conversion and micro hardness of bulk fill composites. Odontology. 2016; 104: 291-297. [22] Flury S, Hayoz S, Peutzfeldt A, Hüsler J, Lussi A. Depth of cure of resin composites: is the ISO 4049 method suitable for bulk fill materials? Dental Materials. 2012; 28: 521-528. [23] Lucey S, Lynch CD, Ray NJ, Burke FM, Hannigan A. Effect of pre‐heating on the viscosity and microhardness of a resin composite. Journal of oral rehabilitation. 2010; 37: 278-282. [24] Moszner N, Fischer UK, Ganster B, Liska R, Rheinberger V. Benzoyl germanium derivatives as novel visible light photoinitiators for dental materials. Dental Materials. 2008; 24: 901-907. [25] Ilie N, Hickel R. Investigations on a methacrylate-based flowable composite based on the SDR™ technology. Dental Materials. 2011; 27: 348-355. [26] Bucuta S, Ilie N. Light transmittance and micro-mechanical properties of bulk fill vs. conventional resin based composites. Clinical Oral Investigations. 2014; 18: 1991-2000. [27] AlShaafi MM. Factors affecting polymerization of resin-based composites: A literature review. The Saudi Dental Journal. 2017; 29: 48-58. [28] Monterubbianesi R, Orsini G, Tosi G, Conti C, Librando V, Procaccini M, et al. Spectroscopic and Mechanical Properties of a New Generation of Bulk Fill Composites. Front Physiol. 2016; 7: 652. [29] Chung KH, Greener E. Correlation between degree of conversion, filler concentration and mechanical properties of posterior composite resins. Journal of Oral Rehabilitation. 1990; 17: 487-494. [30] Garcia D, Yaman P, Dennison J, Neiva GF. Polymerization shrinkage and depth of cure of bulk fill flowable composite resins. Operative Dentistry. 2014; 39: 441-448. [31] Moorthy A, Hogg CH, Dowling AH, Grufferty BF, Benetti AR, Fleming GJ. Cuspal deflection and microleakage in premolar teeth restored with bulk-fill flowable resin-based composite base materials. J Dent. 2012; 40: 500-505. [32] Leprince JG, Leveque P, Nysten B, Gallez B, Devaux J, Leloup G. New insight into the “depth of cure” of dimethacrylate-based dental composites. Dental Materials. 2012; 28: 512-520. [33] Moore BK, Platt JA, Borges G, Chu TM, Katsilieri I. Depth of cure of dental resin composites: ISO 4049 depth and microhardness of types of materials and shades. Operative Dentistry. 2008; 33: 408-412. [34] Price RB, Felix CA, Andreou P. Knoop hardness of ten resin composites irradiated with high-power LED and quartz-tungsten-halogen lights. Biomaterials. 2005; 26: 2631-2641. [35] Bouschlicher MR, Rueggeberg FA, Wilson BM. Correlation of bottom to top surface microhardness and conversion ratios for a variety of resin composite compositions. Operative Dentistry. 2004; 29: 698-704. [36] Asmussen E, Peutzfeldt A. Influence of specimen diameteron the relationship between subsurface depth and hardness of a light-cured resin composite. Eur J Oral Sci. 2003; 111: 543–546. [37] Harrington E, Wilson HJ. Depth of cure of radiation-activatedmaterials- effect of mould material and cavity size. J Dent. 1993; 21: 305–311. [38] Erickson RL, Barkmeier WW. Curing characteristics of a composite. Part 2: The effect of curing configuration on depth and distribution of cure. Dental Materials. 2014; 30: e134-e145. [39] ISO 4049: Dentistry- Polymer-based restorative materials. Geneva, Switzerland: International Organization for Standardization; 2009. Available at: https://www.iso.org/ standard/42898.html. [40] Theodoridis M, Dionysopoulos D, Koliniotou‐Koumpia E, Dionysopoulos P, Gerasimou P. Effect of preheating and shade on surface microhardness of silorane‐based composites. Journal of investigative and clinical dentistry. 2017; 8: e12204. [41] Ilie N, Bauer H, Draenert M, Hickel R. Resin-based composite light-cured properties assessed by laboratory standards and simulated clinical conditions. Operative dentistry. 2013; 38: 159-167. [42] Lee YK. Influence of filler on the difference between the transmitted and reflected colors of experimental resin composites. Dent Mater. 2008; 24: 1243-1247. [43] Halvorson RH, Erickson RL, Davidson CL. The effect of filler and silane content on conversion of resin-based composite. Dent Mater. 2003; 19: 327-333. [44] Czasch P, Ilie N. In vitro comparison of mechanical properties and degree of cure of bulk fill composites. Clinical Oral Investigations. 2013; 17: 227-235. | ||
آمار تعداد مشاهده مقاله: 3,083 تعداد دریافت فایل اصل مقاله: 2,520 |