Dosimetry and Radioenhancement Comparison of Gold Nanoparticles in Kilovoltage and Megavoltage Radiotherapy using MAGAT Polymer Gel Dosimeter | ||
| Journal of Biomedical Physics and Engineering | ||
| مقاله 8، دوره 9، شماره 2، تیر 2019، صفحه 199-210 اصل مقاله (1.27 M) | ||
| نوع مقاله: Original Article | ||
| شناسه دیجیتال (DOI): 10.31661/jbpe.v0i0.827 | ||
| نویسندگان | ||
| S Farahani1، 2؛ N Riyahi Alam* 1؛ S Haghgoo3؛ M Khoobi4، 5؛ Gh Geraily1؛ E Gorji3 | ||
| 1Department of Medical Physics and Biomedical Engineering, Tehran University of Medical Sciences, Tehran, Iran | ||
| 2Students’ Scientific Research Center, Tehran University of Medical Sciences, Tehran, Iran | ||
| 3Pharmaceutical Department, Food & Drug Laboratory Research Center, Food & Drug Organization (FDO), Tehran, Iran. | ||
| 4Nanobiomaterials Group, Pharmaceutical Sciences Research Center, Tehran University of Medical Sciences, Tehran 141761411, Iran | ||
| 5Department of Pharmaceutical Biomaterials and Medical Biomaterials Research Center, Faculty of Pharmacy, Tehran University of Medical Sciences, Tehran, Iran | ||
| چکیده | ||
| Background: Numerous unique characteristics of the nanosized gold, including high atomic number, low toxicity, and high biocompatibility make it one of the most appropriate nanostructures to boost radiotherapy efficacy. Many in-vivo and in-vitro investigations have indicated that gold nanoparticles (AuNPs) can significantly increase tumor injuries in low kilovoltage radiotherapy. While deep-lying tumors require much higher energy levels with greater penetration power, and investigations carried out in megavoltage energy range show contradictory results. Objective: In this study, we quantitatively assess and compare dose enhancement factors (DEFs) obtained through AuNPs under radiation of Cobalt-60 source (1.25MeV) versus Iridium-192 source (380 KeV) using MAGAT gel dosimeter. Material and Methods: MAGAT polymer gel in both pure and combined with 0.2 mM AuNPs was synthesized. In order to quantify the effect of energy on DEF, irradiation was carried out by Co-60 external radiotherapy and Ir-192 internal radiotherapy. Finally, readings of irradiated and non-irradiated gels were performed by MR imaging. Results: The radiation-induced R2 (1/T2) changes of the gel tubes doped with AuNPs compared to control samples, upon irradiation of beams released by Ir-192 source showed a significant dose enhancement (15.31% ±0.30) relative to the Co-60 external radiotherapy (5.85% ±0.14). Conclusion: This preliminary study suggests the feasibility of using AuNPs in radiation therapy (RT), especially in low-energy sources of brachytherapy. In addition, MAGAT polymer gel, as a powerful dosimeter, could be used for 3D visualization of radiation dose distribution of AuNPs in radiotherapy. | ||
| کلیدواژهها | ||
| Brachytherapy؛ Dose Enhancer؛ External Radiotherapy؛ Gel Dosimetry؛ Nanotechnology | ||
| مراجع | ||
|
| ||
|
آمار تعداد مشاهده مقاله: 2,387 تعداد دریافت فایل اصل مقاله: 2,277 |
||