An Update of Couch Effect on the Attenuation of Megavoltage Radiotherapy Beam and the Variation of Absorbed Dose in the Build-up Region | ||
| Journal of Biomedical Physics and Engineering | ||
| مقاله 9، دوره 7، شماره 3، 2017، صفحه 279-288 اصل مقاله (614.18 K) | ||
| نوع مقاله: Original Research | ||
| نویسندگان | ||
| T Sedaghatian1، 2؛ M Momennezhad3، 4؛ S H Rasta* 2، 5، 6؛ Y Makhdoomi4؛ S Abdollahian4 | ||
| 1Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Science, Tabriz, Iran | ||
| 2Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran | ||
| 3Department of Medical Physics, Faculty of Medicine, Mashhad University of Medical Sciences, Iran | ||
| 4Radiotherapy and Oncology Reza Center, Mashhad, Iran | ||
| 5Department of Medical Bioengineering, Tabriz University of Medical Sciences, Iran | ||
| 6Faculty of Medical Sciences, University of Aberdeen, UK | ||
| چکیده | ||
| Purpose: Fiber carbon is the most common material used in treating couch as it causes less beam attenuation than other materials. Beam attenuation replaces build-up region, reduces skin-sparing effect and causes target volume under dosage. In this study, we aimed to evaluate beam attenuation and variation of build-up region in 550 TxT radiotherapy couch. Materials and Methods: In this study, we utilized cylindrical PMMA Farmer chamber, DOSE-1 electrometer and set PMMA phantom in isocenter of gantry and the Farmer chamber on the phantom. Afterwards, the gantry rotated 10°, and attenuation was assessed. To measure build-up region, we used Markus chamber, Solid water phantom and DOSE-1 electrometer. Doing so, we set Solid water phantom on isocenter of gantry and placed Markus chamber in it, then we quantified the build-up region at 0° and 180° gantry angels and compared the obtained values. Results: Notable attenuation and build-up region variation were observed in 550 TxT treatment table. The maximum rate of attenuation was 5.95% for 6 MV photon beam, at 5×5 cm2 field size and 130° gantry angle, while the maximum variation was 7 mm for 6 MV photon beam at 10×10 cm2 field size. Conclusion: Fiber carbon caused beam attenuation and variation in the build-up region. Therefore, the application of fiber carbon is recommended for planning radiotherapy to prevent skin side effects and to decrease the risk of cancer recurrence. | ||
| کلیدواژهها | ||
| Beam Attenuation؛ Carbon Fiber؛ Couch Insert؛ Surface Dose؛ Megavoltage Radiotherapy | ||
| مراجع | ||
|
| ||
|
آمار تعداد مشاهده مقاله: 1,110 تعداد دریافت فایل اصل مقاله: 1,059 |
||