| تعداد نشریات | 20 |
| تعداد شمارهها | 1,266 |
| تعداد مقالات | 11,540 |
| تعداد مشاهده مقاله | 81,960,921 |
| تعداد دریافت فایل اصل مقاله | 121,091,853 |
Development and Validation of an Enantioselective HPLC–UV Method for Stereospecific Therapeutic Drug Monitoring of Methadone Enantiomers in Iranian MMT Patients: A Pilot Study | ||
| Trends in Pharmaceutical Sciences and Technologies | ||
| مقاله 6، دوره 12، شماره 1، خرداد 2026 | ||
| نوع مقاله: Original Article | ||
| شناسه دیجیتال (DOI): 10.30476/tips.2026.110754.1352 | ||
| نویسندگان | ||
| Hashem Montaseri* 1؛ batool faegheh bahaaldini biggi zarandi2؛ Marzieh Faraz3 | ||
| 1department of Quality Control, Shiraz Faculty of Pharmacy, Shiraz University of medical Sciences, Shiraz, Fars. IR | ||
| 2Department of Pharmacology, Faculty of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran | ||
| 3Department of Quality Control, Faculty of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran | ||
| چکیده | ||
| Background: Methadone used in maintenance therapy is a racemic mixture of R- and S-enantiomers with distinct pharmacological and safety profiles. R-methadone mediates therapeutic effects via μ-opioid receptor activation, whereas S-methadone inhibits hERG potassium channels and may contribute to QT prolongation. Iran hosts the largest national methadone maintenance therapy (MMT) population (>800,000 patients), yet enantioselective therapeutic drug monitoring (TDM) is not available. Objectives: To develop, validate, and clinically apply a simple and cost-effective HPLC–UV method for enantioselective quantification of methadone in plasma of Iranian MMT patients. Methods: Plasma samples from 20 clinically stable MMT patients (60–120 mg/day) were analyzed. Enantiomers were separated on a Chiral-AGP column (100 × 4 mm, 5 µm) using isocratic acetonitrile:0.01 M phosphate buffer (15:85, pH 6.8) at 1.2 mL/min with UV detection at 210 nm. Validation followed ICH Q2(R1) guidelines. Liquid–liquid extraction with n-hexane and imipramine as internal standard was applied. Results: Calibration was linear (12.5–1000 ng/mL; r² ≥ 0.999). LOQ was 10 ng/mL. Intra- and inter-day precision were <3%, accuracy within ±3%, recovery 91–94%, and matrix effects 95–102% (CV <4.5%). Trough concentrations showed high variability: total methadone 452 ± 185 ng/mL; R- 226 ± 92 ng/mL; S- 181 ± 74 ng/mL; R:S ratio 0.6–1.9. Only 45% of patients were within the therapeutic R-methadone range (100–250 ng/mL), while 10% exhibited potentially elevated S-methadone levels. Conclusion: This validated, low-cost (~$4/sample) method enables stereospecific methadone monitoring. Marked interindividual variability highlights the clinical value of enantioselective TDM to optimize efficacy and minimize cardiovascular risk in MMT programs | ||
| کلیدواژهها | ||
| Methadone enantiomers؛ HPLC–UV؛ therapeutic drug monitoring؛ chiral analysis؛ methadone maintenance therapy؛ stereoselective pharmacokinetics | ||
|
آمار تعداد مشاهده مقاله: 3 |
||