Background: Despite the implants' remarkable success, mechanical failure of implant-abutment screws is a challenge for clinicians. Among the types of mechanical failures, abutment screw loosening is still frequently reported in the literature Purpose: The present study aimed to evaluate the effect of using lubricant on the detorque force (removal force) of locator/kerator abutment in overdenture patients after 6 months of clinical usage. Materials and Method: This pilot clinical study examined the detorque force of implants in 20 edentulous patients with two mandibular implants positioned between the mental foramen. The patients underwent the fabrication of a complete maxillary prosthesis and mandibular overdenture. Before loading attachments in the delivery session, healing abutments were removed, and implant interiors dried, randomly some fixtures received a tetracycline eye ointment 1% lubricant, while the others remained non-lubricated. Abutments were secured with prescribed torque according to implant system guidelines (20 N.cm). After 6 months, detorque forces for the abutment locators were measured using a torque meter. Descriptive statistics, mean comparison, and Pearson correlation were performed on the obtained data. A significant level of P<0.05 was considered in the present study. Results: The mean detorque force was 13.4±1.94 in the non-lubricated group and 16.35± 1.24 in the lubricated group, which was significantly higher in the lubricated group (p< 0.001). Other results of the study include the non-significance of the difference in detorque force within male and female groups (p> 0.05), as well as the non-significance of Pearson's correlation between patients' age and detorque force (p> 0.05). Conclusion: According to the results, the use of lubricant significantly increases the detorque force, and it is recommended to use tetracycline eye ointment as a lubricant in implant treatment processes. |
- Oshida Y, Tuna EB, Aktören O, Gençay K. Dental Implant Systems. Int J Mol Sci. 2010; 11: 1580-1678.
- Mohajerani H, Roozbayani R, Taherian S, Tabrizi R. The risk factors in early failure of dental implants: a retrospective study. J Dent Shiraz Univ Med Sci. 2017; 18: 298.
- Do TA, Le HS, Shen YW, Huang HL, Fuh LJ. Risk factors related to late failure of dental implant: A systematic review of recent studies. Int J Environ Res Public Health. 2020; 17: 3931.
- Hanif A, Qureshi S, Sheikh Z, Rashid H. Complications in implant dentistry. Eur J Dent. 2017; 11: 135-140.
- Taylor TD. Prosthodontic problems and limitations associated with osseointegration. JPD. 1998; 79: 74-78.
- Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications with implants and implant prostheses. J Prosthet Dent. 2003; 90: 121-132.
- Hernández-González D, Marincola M, Diaz-Caballero A, Passaretti A, Cicconetti A. Survival rate, biomechanical complications, and patient satisfaction of implant-supported FRC full-arch prostheses: A retrospective study with follow up of 5 years. J Dent Shiraz Univ Med Sci. 2024; 25: 268-274.
- Kreissl ME, Gerds T, Muche R, Heydecke G, Strub JR. Technical complications of implant‐supported fixed partial dentures in partially edentulous cases after an average observation period of 5 years. Clin Oral Implants Res. 2007; 18: 720-726.
- Lee KY, Shin KS, Jung JH, Cho HW, Kwon KH, Kim YL. Clinical study on screw loosening in dental implant prostheses: a 6-year retrospective study. J Korean Assoc Oral Maxillofac Surg. 2020; 46: 133.
- Siamos G, Winkler S, Boberick KG. The relationship between implant preload and screw loosening on implant-supported prostheses. J Oral Implantol. 2002; 28: 67-73.
- Wu T, Fan H, Ma R, Chen H, Li Z, Yu H. Effect of lubricant on the reliability of dental implant abutment screw joint: An in vitro laboratory and three-dimension finite element analysis. Mater Sci Eng C. 2017; 75: 297-304.
- Derafshi R, Mohaghegh M, Saki M, Safari A, Haghighi MR. The effects of denture cleansing solutions on the retention of attachments of implant supported overdentures. J Dent Shiraz Univ Med Sci. 2015; 16(1 Suppl): 68.
- Schulz KF, Altman DG, Moher D. Consort 2010 statement: updated guidelines for reporting parallel group randomised trials. J Pharmacol Pharmacother. 2010; 1: 100-107.
- Byrne D, Jacobs S, O'Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J Prosthodont. 2006; 15: 164-171.
- Huang Y, Wang J. Mechanism of and factors associated with the loosening of the implant abutment screw: a review. J Esthet Restor Dent. 2019; 31: 338-345.
- Schulte JK, Coffey J. Comparison of screw retention of nine abutment systems: a pilot study. Implant Dent. 1997; 6: 29-32.
- Vallee MC, Conrad HJ, Basu S, Seong WJ. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants. J Prosthet Dent. 2008; 100: 86-92.
- Nigro F, Sendyk CL, Francischone*Jr CE, Francischone CE. Removal torque of zirconia abutment screws under dry and wet conditions. Braz Dent J. 2010; 21: 225-228.
- Duarte AR, Neto JPS, Souza JC, Bonachela WC. Detorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution. J Prosthodont. 2013; 22: 275-281.
- Stüker RA, Teixeira ER, Beck JCP, Costa NPd. Preload and torque removal evaluation of three different abutment screws for single standing implant restorations. J Appl Oral Sci. 2008; 16: 55-58.
- Tsuge T, Hagiwara Y. Influence of lateral-oblique cyclic loading on abutment screw loosening of internal and external hexagon implants. Dent Mater J. 2009; 28: 373-381.
- Asli HN, Saberi BV, Fatemi AS. In vitro effect of chlorhexidine gel on torque and detorque values of implant abutment screw. Indian J Dent Res. 2017; 28: 314-319.
- Norton MR. Assessment of cold welding properties of the internal conical interface of two commercially available implant systems. J Prosthet Dent. 1999; 81: 159-166.
- Basílio MdA, Abi‐Rached FdO, Butignon LE, Arioli*Filho JN. Influence of Liquid Lubrication on the Screw‐Joint Stability of Y‐TZP Implant Abutment Systems. J Prosthodont. 2017; 26: 656-658.
- Tzenakis GK, Nagy WW, Fournelle RA, Dhuru VB. The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws. J Prosthet Dent. 2002; 88: 183-191.
- Martin WC, Woody RD, Miller BH, Miller AW. Implant abutment screw rotations and preloads for four different screw materials and surfaces. J Prosthet Dent. 2001; 86: 24-32.
- Nithyapriya S, Ramesh A, Kirubakaran A, Mani J, Raghunathan J. Systematic analysis of factors that cause loss of preload in dental implants. J Indian Prosthodont Soc. 2018; 18: 189.
- Seddigh MA, Mostafavi AS. Implant Abutment Screw Loosening: A Review of Effective Factors. J Clin Diag Res. 2019; 13: 6-9.
- Chitsazi MT, Khorramdel A, Mesforoush MA. Effect of sterile tetracycline ophthalmic ointment as an adjuvant to mechanical debridement on the treatment of peri-implantitis: A randomized controlled clinical trial. J Adv Periodontol Implant Dent. 2022; 14: 26.
- Mirzaali F, Dizaj SM, Shahi S, Yousef*Memar M, Parnia F. The antibacterial effect of tetracycline-loaded mesoporous silica nanoparticles in the gingival fluid at implant-abutment junction: a randomized clinical trial study. Pharm Nanotechnol. 2023; 11: 208-216.
|